US Data Centre - AtlantaNAP - Atlanta, Georgia
Our Atlanta based data centre, AtlantaNAP offers fully qualified remote hands - available 24 x 7 x 365 days a year for anything from router support to linux and windows system administration.
Server hardware support for certain common items including: standard hard drives, RAM, CPU's, Server Boards and telcom equipemtn swap for emergency replacement.
Our Atlanta data centre is fully equipped with multiple power generators on a redundant grid with two separate feeds into the building. This, and redundant internet connections provides our customers with the best possible uptime for your dedicated server, and colocation servers in Atlanta, Georgia. When uptime counts, our Atlanta Colocation can help.
Security
Security starts from the moment you enter the building with 10 foot high razor wire fences surrounding the 4 acre property, all of which is covered by security lights and cameras. All footage from the cameras is stored on a specially built security server with redundant storage. Entrance through the main gate requires a keycard or manual access granted by our onsite security guards and happens through an electric gate for customers' convenience. The front door is again protected by a key card reader. After entering the gate, there are three locked/key carded doors protecting the datacenter and a biometric hand scanner authentication. Once inside the datacenter itself, customers assets are protected by locked secure cabinets or cages. All assets entering or being removed from the building are logged by an onsite security guard. Our guard service is managed by a duly sworn armed police officer with arrest powers.Power
The Atlanta NAP is one of the few facilities able to support even your most power dense applications. Power is dual fed from the grid and protected though our redundant paralleled power system, configured with an additional full wrap-around bypass for extra redundancy (we are able to take the system offline for any type of internal maintenance without dropping power to the facility). The UPS system is backed up by a state of the art parallel generator system with multiple generators running in N+1 format. These are computer controlled and automated. The generators have 150 gallon day tanks fed from redundant pumps from our 12,000 gallon reserve tank. The system is powered by state of the art by Cummins turbocharged generators and digital fuel management system by Simplex and Veeder-RootCooling Systems
The Atlanta NAP currently has 1000 tons of cooling piped into its 50,000 sq. foot datacenter. With pre planned capacity of over 2000 tons, cooling will never be an issue. Each bank of cooling towers utilizes state of the art energy management technology. As with all core system, the cooling towers are N+1, fed by redundant N+1 pumps. The Atlanta NAP also has a 30,000 gallon reserve water tank in case the city water supply ever fails.Fire Protection
The Atlanta NAP uses a state of the art dual interlock dry pipe fire suppression system. High-tech smoke detectors signal the pipes to switch from compressed air (so Atlanta NAP staff are instantly alerted of leaks) to water. Then if a sprinkler head is set off by an actual fire water is deployed to the affected zone only. The system is monitored through the building management system. The floors are all equipped with floor drains on 20 foot centers that drain the building in case of any water.Connectivity
Sitting on one of AGL's main fiber backbones, the Atlanta NAP operates a metro Ethernet ring based on Extreme Networks 10 Gig technology with Sonet like EAPS implementation for sub 50 ms reroute times utilizing Ethernet for efficient and affordable equipment connectivity. We have collocation in Telx at 56 Marietta and Switch and Data at 56 Marietta and are able to offer you 100 mb and Gigabit Ethernet metro cross connects to any one of the more than 100 carriers located in the Telx building. The ring is currently lit at 10 gig.Equipment Load-in, Load-out
The Atlanta NAP offers drive up docks on the front of the building for easy delivery of your freight and we maintain a full drive in door and loading bay on the rear of the building for inclement weather loads as well. There are no elevator loads to worry about since the facility is one story.Floor Loading
The Atlanta NAP used to be a main warehouse with heavy operations and fork lift operation inside. The floors are 10 inch thick concrete with 1 inch rebar, so there are no floor load limitations for currently known computer and telco equipment including battery operations and UPS systems.Would you like us to quote you a price for your individual requirement? Give us a call today on: + 44 (0)207 099 2181, or contact us through our online contact centre.